PCG55x ATM to Medium Vacuum Gauge

 

The INFICON Pirani Capacitance Diaphragm Gauge (PCG55x) combines the INFICON Pirani technology with the advantages of a ceramic capacitance diaphragm sensor in a single product.

In the measurement range between 10 mbar and atmosphere the capacitance diaphragm technology provides gas-type independent, highly accurate values for reliable pressure measurement. The PCG55x offers also a variety of features which allows the right product configuration for the demanded application.

This Pirani Capacitance Diaphragm Gauge series PCG550, PCG552, PCG554 direct replacement for TTR 101 series:

 

Part-No              Typ        Part-No      Typ       
3PC1-001-0000PCG550FCC,16KF=230350 V01TTR 101TTR 101, FCC, 16 KF
3PC1-00F-0000PCG550FCC,1/8NPT=230351 V01TTR 101FCC, 1/8 NPT
3PC1-001-2000PCG550FCC,2SP,16KF=230352 V01TTR 101 FCC, 16 KF, 2SP
3PC1-00F-2000PCG550FCC,2SP,1/8NPT=230353 V01TTR 101 FCC, 1/8 NPT, 2SP
3PC1-001-1000PCG550FCC,LCD,16KF=230354 V01TTR 101FCC, 16 KF, LCD
3PC1-00E-1000PCG550FCC,LCD,1/8NPT=230355 V01TTR 101FCC, 1/8 NPT, LCD
3PC1-001-4000PCG550FCC,2SP,LCD,16KF=230356 V01TTR 101 FCC, 16 KF, 2SP, LCD
3PC1-00F-4000PCG550FCC,2SP,LCD,1/8" NPT=230357 V01TTR 101 FCC, 1/8 NPT, 2SP, LCD
3PC1-001-2020PCG550FCC,2SP, PBus,16KF=230358 V01TTR 101 FCC, 16KF, 2SP, PBUS
3PC3-001-0000PCG554FCC,16KF=230 363 V01TTR 101CC, FCC,16 KF
357-925PCG550Spare-Sensor DN16 ISO-KF=230361 V01TTR 101
357-930PCG550Spare-Sensor 1/8" NPT=230362 V01TTR 101
357-947PCG554Spare-Sensor DN16 ISO-KF=nonesuited for TTR 101 CC

 

Also all known TTR 101 spare sensor heads can be replaced with PCG550, PCG552 and PCG554 spare sensor heads.

Benefits

  • The PCG550 is a direct replacement for TTR 101 Pirani Capacitance Diaphragm Transmitter series

    Gas type independent above 10 mbar – allows safe venting with any gas mixture

  • High accuracy and reproducibility at atmosphere – for reliable, fast atmospheric pressure detection
  • Versatile of mounting orientation – provides engineering freedom in tool design
  • Available with Tungsten (PCG550) or Nickel (PCG552) filament or with a fully ceramic coated (PCG554) sensor unit for highly corrosive applications
  • Easy to exchange plug & play sensor element with on-board calibration data – guarantees high reproducibility and low cost of ownership
  • Selectable output signal for easy integration
  • Optional atmospheric switch, display and digital interfaces
  • Compliance & standards: CE, EN, UL, CSA, RoHS

Typical Applications

  • Load Lock control
  • Fore vacuum pressure measurement
  • Safety circuits in vacuum systems
  • General vacuum measurement and control in the medium and rough vacuum range

News

PCG550, PCG552 and PCG554 series is 100% drop in replacement for TTR 101 Vacuum Transmitters

NEW! With EtherCAT digital interface available now !

  • tiba42e1 Massbild mit EtherCAT und Stecker.png

Specifications

Type PCG550 Tungsten PCG554 ceramic coated
Measurement range 5×10-5 … 1500 5×10-5 … 1500
Accuracy    
5×10-4 … 1×10-3 mbar (N2) % of reading ±50 ±50
1×10-3 … 100 mbar (N2) % of reading ±15 ±15
100 … 950 mbar % of reading ±5 ±5
950 … 1050 mbar % of reading ±2.5 ±2.5
Repeatability    
1×10-3 … 1100 mbar (N2) % of reading ±2 ±2
Admissible pressure bar (absolute) ≤5 ≤5
Pressure, max. bar (absolute) ≥10 ≥10
Admissible temperature    
Operation (ambient) °C +10 … +50 +10 … +50
Storage °C -20 … +65 -20 … +65
Bakeout at flange °C ≤80 ≤80
Bakeout at flange long tube °C ≤250 ≤250
Supply voltage V (dc) +15 … +30 +15 … +30
Power consumption    
Without fieldbus W ≤2.5 ≤2.5
DeviceNet™ W ≤3 ≤3
Profibus W ≤3 ≤3
Output signal analog 3PCx-0xx-xxx0 V 0 … +10.23 0 … +10.23
Output signal analog 3PCx-0xx-xxx1 V 0 … +8.68 0 … +8.68
Output signal analog 3PCx-0xx-xxx2 V 0 … +5.659 0 … +5.659
Output signal analog 3PCx-0xx-xxx3 V 0 … +9.05 0 … +9.05
Measuring range 3PCx-0xx-xxx0 V +0.61 … +10.23 +0.61 … +10.23
Measuring range 3PCx-0xx-xxx1 V +1.2 … +8.68 +1.2 … +8.68
Measuring range 3PCx-0xx-xxx2 V +0.375 … +5.659 +0.375 … +5.659
Measuring range 3PCx-0xx-xxx3 V +1.57 … +9.05 +1.57 … +9.05
Voltage vs. pressure    
3PCx-0xx-xxx0 volts per decade 1.286 1.286
3PCx-0xx-xxx1 / -xxx2 / -xxx3 volts per decade 1 1
Load impedance kΩ >10 >10
Setpoint relay    
Number of setpoints 2 2
Range (N2) mbar 5×10-5 … 1000 5×10-5 … 1000
Relay contact n.o., potential free n.o., potential free
Hysteresis % of threshold 10 10
Contact rating solid state relays ≤30 ≤30
Contact rating mechanical relays ≤30 ≤30
Switching time ms ≤30 ≤30
Interface (digital) RS232C RS232C
Electrical connection    
3PCx-0xx-x0xx FCC, 8-pin FCC, 8-pin
3PCx-0xx-x1xx D-Sub, 9-pin, male D-Sub, 9-pin, male
3PCx-0xx-x2xx D-Sub, 15-pin HD, male D-Sub, 15-pin HD, male
3PCx-0xx-x4xx D-Sub, 15-pin HD, with RS485, male D-Sub, 15-pin HD, with RS485, male
Cable length m (ft.) ≤100 (≤330) ≤100 (≤330)
RS232C operation m (ft.) ≤30 (≤100) ≤30 (≤100)
Materials exposed to vacuum W, Ni, NiFe, Al2O3, SnAg, stainless steel, glass Al2O3, stainless steel
Internal volume    
DN 16 ISO-KF cm³ 4.7 4.7
DN 16 ISO-KF long tube cm³ 14.5 14.5
DN 16 CF-F cm³ 8 8
DN 16 CF-R long tube cm³ 14 14
DN 25 ISO-KF, 4 VCR cm³ 5.5 5.5
8 VCR cm³ 7 7
1/8'' NPT, 7/16-20 UNF cm³ 5.2 5.2
Surface mount 29 mm/1.15 inch cm³ 4.9 4.9
4 VCR 90° cm³ 7.9 7.9
Weight    
Without fieldbus interface g 115 … 130 115 … 130
With fieldbus interface g 230 … 250 230 … 250
Degree of protection IP 40 IP 40
Standards    
CE conformity EN 61000-6-2/-6-3, EN 61010 EN 61000-6-2/-6-3, EN 61010
ETL certification UL 61010-1, CSA 22.2 No.61010-1 UL 61010-1, CSA 22.2 No.61010-1
DeviceNet™    
Protocol DeviceNet™, group 2 slave only DeviceNet™, group 2 slave only
Data rate switch kBaud 125, 250, 500 or network programmable 125, 250, 500 or network programmable
Cable length 125 kbps m (ft.) 500 (1650) 500 (1650)
Cable length 250 kbps m (ft.) 250 (825) 250 (825)
Cable length 500 kbps m (ft.) 100 (330) 100 (330)
MAC ID 2 switches (address 00 - 63) or network programmable 2 switches (address 00 - 63) or network programmable
Digital functions read pressure, select units: Torr, mbar, Pa, micron, counts; monitor gauge status, detailed alarm and warning information, safe state allows definition of behavior in case of error read pressure, select units: Torr, mbar, Pa, micron, counts; monitor gauge status, detailed alarm and warning information, safe state allows definition of behavior in case of error
Specification DeviceNet™ "Vacuum Gauge Device Profile" DeviceNet™ "Vacuum Gauge Device Profile"
Device type ''CG'' for combination gauge ''CG'' for combination gauge
I / O slave messaging polling only polling only
Supply voltage for DeviceNet™ 3PI6- / 3PI7- / 3PI8-0xx-xxxx V (dc) +15 … +30 +15 … +30
Power consuption 3PI6- / 3PI7- / 3PI8-0xx-xxxx W ≤3 ≤3
Connector for DeviceNet Micro-Style, 5-pin, male Micro-Style, 5-pin, male
Profibus DP    
Baud rates 9.6 / 19.2 / 93.75 / 187.5 / 500 9.6 / 19.2 / 93.75 / 187.5 / 500
Address 2 switches (address 00 - 127) or network programmable 2 switches (address 00 - 127) or network programmable
Digital functions read pressure, select units: Torr, mbar, Pa, micron, counts; monitor gauge status, detailed alarm and warning information, safe state allows definition of behavior in case of error read pressure, select units: Torr, mbar, Pa, micron, counts; monitor gauge status, detailed alarm and warning information, safe state allows definition of behavior in case of error
Connector for Profibus DP D-Sub, 9-pin, female D-Sub, 9-pin, female
RS485C    
Baud rates kBaud 9.6 / 19.2 / 38.4 /57.6 9.6 / 19.2 / 38.4 /57.6
Address 2 switches (address 00 - 255) 2 switches (address 00 - 255)
Digital functions read pressure, select units: Torr, mbar, Pa, micron, counts; monitor gauge status, detailed alarm and warning information, safe state allows definition of behavior in case of error read pressure, select units: Torr, mbar, Pa, micron, counts; monitor gauge status, detailed alarm and warning information, safe state allows definition of behavior in case of error
Connector for RS485 D-Sub, 15-pin HD, male D-Sub, 15-pin HD, male
EtherCAT    
Protocol EtherCAT protocol specialized for EtherCAT protocol specialized for EtherCAT
Communication standards ETG.5003 Part 1 "Semiconductor Device Profile" ETG.5003 Part 2080 "Specific Device Profile: Vacuum Pressure Gauge" ETG.5003 Part 1 "Semiconductor Device Profile" ETG.5003 Part 2080 "Specific Device Profile: Vacuum Pressure Gauge"
Node address Explicit Device Identification Explicit Device Identification
Physical layer 100BASE-Tx (IEEE 802.3) 100BASE-Tx (IEEE 802.3)
EtherCAT connector RJ45, 8-pin (socket), IN and OUT RJ45, 8-pin (socket), IN and OUT
Cable shielded Ethernet CAT5e or higher shielded Ethernet CAT5e or higher
Cable length m (ft.) ≤100 (330) ≤100 (330)
Process data Fixed PDO mapping and configurable PDO mapping Fixed PDO mapping and configurable PDO mapping
Mailbox (CoE) SDO requests, responses and information SDO requests, responses and information

Part Number

PCG550 Tungsten
Part Number Description
3PC1-001-0000 PCG550 FCC,16KF
3PC1-00F-0000 PCG550 FCC,1/8NPT
3PC1-001-2000 PCG550 FCC,2SP,16KF
3PC1-00F-2000 PCG550 FCC,2SP,1/8NPT
3PC1-001-1000 PCG550 FCC,LCD,16KF
3PC1-001-4000 PCG550 FCC,2SP,LCD,16KF
357-925 PCG550 Spare Sensor, DN16ISO-KF
357-930 PCG550 Spare Sensor, 1/8" NPT
PCG554 ceramic coated
Part Number Description
3PC3-001-0000 PCG554 FCC,16KF

Accessories

PCG550 Tungsten
Part Number Description
211-001 Clamping ring DN 10-16 ISO-KF
211-097 Centering ring with fine filter DN 16 KF
303-333 Diagnostic cable 1.9m (P3)
PCG554 ceramic coated
Part Number Description
211-001 Clamping ring DN 10-16 ISO-KF
211-097 Centering ring with fine filter DN 16 KF
303-333 Diagnostic cable 1.9m (P3)